| Form Factor |
| 2U Rack-Mount Server — SSI Thin E-Bay v3.1 -compatible |
| Dimensions and Color |
Height 3.45", Width 16.93", Depth 26.46" (87.5 mm x 430 mm x 672 mm)
Black (Intel Color Standard GE 701) |
| Hard-Drive and Peripheral-Bay Support |
| Fixed |
Up to three SATA |
| Hot-Swap |
Up to six SATA or SCSI4 |
| External Peripheral Bay |
Tool-less slimline bay for a slimline CD, DVD, or floppy drive; option to convert a hard-drive bay into a slimline-floppy bay; options: drive bay 1 configurable to support CD or floppy drive, drive bay 6 configurable to support tape drive |
| System Cooling (shipping configuration) |
| Four 60mm fans in tool-less fan module with the option to add four more 60mm fans for redundant cooling; fans provide cooling for the processors, hard drives, and add-in cards; two 40mm fans per power-supply module for cooling the power-supply module; all system fans instrumented to provide RPM data for fan-failure prediction and detection; all fans can be monitored by Intel® Server Management 8 |
| Power Delivery |
| DC Power Supply |
700W PFC hot-swap power modules that can be configured in a 0+1 or a redundant 1+1² configuration |
| AC Voltage |
100-127 / 200-240 V~; 8.9/ 5.4A5 |
| +5V |
12A maximum |
| +5V Standby |
2A maximum |
| +12V |
58A maximum continuous |
| +3.3V |
16A maximum |
| -12V |
0.5A maximum |
| Control Panel |
| Buttons and Switches |
Power on/off (momentary) button, system-reset button, system-ID button, tool-activated NMI switch |
| LEDs |
Power, hard-drive activity, network activity (two), system ID, general system status |
| Connectors |
USB port, video (switched video with rear video connector) |
| Intel® Local Control Panel¹ (optional) |
For monitoring and control of the server from the front panel |
| Security |
| Optional mechanical locking on the front bezel, an intrusion switch that can be monitored by Intel® Server Management 8 |
| Environment |
| Ambient Temperature |
Operating: +10°C to +35°C; non-operating: -40°C to +70°C |
| Relative Humidity |
Non-operating: 95% @ +30°C non-condensing |
| Acoustics |
5.7 bels actual |
| Electrostatic Discharge |
15kV air discharge and 8kV direct contact per Intel test specification |
Safety and EMC Regulatory Compliance (Class A) (EMC regulatory compliance is based on integration with a validated Intel server board and configuration as outlined in the Intel® Server Chassis SR2400 subassembly guide.) |
| Country and District |
Certification Safety and/or EMC |
Regulatory Marks Safety and/or EMC
|
| Argentina |
IRAM |
Not applicable |
| Australia/New Zealand |
ACA, MED |
C-Tick |
| Belarus |
Bellis |
Not applicable |
| Canada |
UL / Industry Canada |
cULus / ICES |
| China |
CNCA |
CCC |
| Europe |
European Directives |
CE |
| Germany |
GS |
GS |
| International |
CB Report / CISPR |
Not Applicable |
| Japan |
VCCI |
VCCI |
| Korea |
RRL |
MIC |
| Russia |
GOST |
GOST |
| Taiwan |
BSMI RPC |
BSMI |
| United States |
UL / FCC |
CULus / FCC |