| Form Factor |
| 1U Rack-Mount Server — SSI Thin E-Bay v3.1 -compatible |
| Dimensions and Color |
Height 1.7", Width 16.93", Depth 26.46" (43 mm x 430 mm x 672 mm)
Black (Intel Color Standard GE 701) |
| Hard-Drive-Bay Support |
| Fixed |
Up to three SATA or IDE (one-inch height) |
| Hot-Swap |
Up to three SATA or SCSI (one-inch height) |
| Peripheral Bay |
Tool-less slimline bay for a slimline CD, CD/DVD, or floppy drive; option to convert a hard-drive bay into a slimline floppy bay |
| System Cooling |
| Four dual-rotor 56mm fans and one single-rotor 28mm fan mounted in tool-less fan module and providing cooling for the processors, hard drives, and add-in cards; two 28mm fans for cooling the power supply; all fans monitored by Intel® Server Management 8 and instrumented to provide RPM data for fan-failure prediction and detection |
| Power Delivery |
| DC Power Supply |
500W PFC |
| AC Voltage |
100 127 / 200 240 V~; 6.5 / 3.2A² |
| +5V |
12A maximum |
| +5V Standby |
2A maximum |
| +12V |
35A maximum continuous |
| +3.3V |
16A maximum |
| -12V |
0.5A maximum |
| Control Panel |
| Buttons and Switches |
Power on/off (momentary) button, system reset button, ACPI sleep switch, tool-activated NMI switch |
| LEDs |
Power, hard-drive activity, network activity (two), system ID (rack only), general system status, hot-swap and redundant-fan activity |
| Connectors |
USB port, video (switched video with rear video connector) |
| Intel® Local Control Panel (optional) |
For monitoring and control of the server from the front panel |
| Security |
| Optional mechanical locking on the front bezel, an intrusion switch that can be monitored by Intel® Server Management 8 |
| Environment |
| Ambient Temperature |
Operating: +10°C to +35°C; non-operating: -40°C to +70°C |
| Relative Humidity |
Non-operating: 95% @ +30°C non-condensing |
| Acoustics |
5.7 bels actual |
| Electrostatic Discharge |
15kV air discharge, 8kV direct contact per Intel test specification |
Safety and EMC Regulatory Compliance (Class A) (EMC regulatory compliance is based on integration with a validated Intel server board and configuration as outlined in the Intel® Server Chassis SR1400 subassembly guide.) |
| Country and District |
Certification Safety and/or EMC |
Regulatory Marks Safety and/or EMC
|
| Argentina |
IRAM |
Not applicable |
| Australia/New Zealand |
ACA, MED |
C-Tick |
| Belarus |
Bellis |
Not applicable |
| Canada |
UL / Industry Canada |
cULus / ICES |
| China |
CNCA |
CCC |
| Europe |
European Directives |
CE |
| Germany |
GS |
GS |
| International |
CB Report / CISPR |
Not Applicable |
| Japan |
VCCI |
VCCI |
| Korea |
RRL |
MIC |
| Russia |
GOST |
GOST |
| Taiwan |
BSMI RPC |
BSMI |
| United States |
UL / FCC |
CULus / FCC |