Intel SR2300 Internet Server Platform: Maximum Density with In-the-Box Scalability

Intel SR2300 Overview
Intel SR2300 Features
Intel SR2300 Datasheet
Intel SR2300 Specifications
Intel SR2300 Virtual Tour
Intel SR2300 Tech Forum
Intel SR2300 Buy Now
Form Factor
2U rack-mount server chassis for EIA Standard 310-D racks, validated with Intel® Server Board SE7501WV2
Dimensions and Color
3.4” (height) x 16.9” (width) x 24” (depth) (chassis without handles); 3.4” (height) x 18.9” (width) x 25.1” (depth) (chassis with handles); black trim
Hard Drive Support
Drive Bays Six one-inch hot-swap, one universal (for hot-swap drive, CD-ROM/floppy or DVD/floppy drive), one 3.5-inch full height
LVD SCSI Backplane Ultra320/Ultra160 support for up to seven one-inch hot-swap hard drives or six one-inch hot-swap drives and one slim-line CD-ROM/floppy drive module
System Cooling
480W Power Supply Configuration Three 60mm fans mounted in the middle of the chassis and instrumented to provide RPM data for fan-failure prediction and detection (optional fourth fan available for redundant cooling); One 80mm x 38mm power-supply fan
500W Power Supply Configuration Three 60mm fans mounted in the middle of the chassis and instrumented to provide RPM data for fan-failure prediction and detection (optional fourth fan available for redundant cooling); One 60mm x 38mm power-supply fan
Front Panel
Buttons and Switches Power/sleep, reset, NMI, and ID
LEDs Power, hard-drive activity, network activity, system ID, and general system status
Connectors VGA Video Port, USB Port
Security
A mechanical lock on the optional front bezel and an intrusion switch that can be monitored by Intel® Server Management
Environment
Ambient Temperature Operating (system): 10°C to +35°C, with maximum change not to exceed 10°C ; non-operating (system): -40°C to +70°C
Relative Humidity Non-operating: 90% @ 35°C non-condensing
Acoustics <55 dBA (rack-mount) in an idle state in an normal office environment (23°C)
Electrostatic Discharge 15kV per Intel test specification

Standard Power Supply
AC Power Supply One fixed 480W EPS (non-redundant option) or one 500W hot-swap SSI TPS 1+0 (redundant option)
Max AC Voltage (500W) One fixed 480W EPS (non-redundant option) or one 500W hot-swap SSI TPS 1+0 (redundant option)
Max AC Voltage (480W) 8.4A at 115V, 4.2A at 220V
+5V 20A max
+5V Standby 2A max
+12V1 18A sustained
+12V2 18A sustained
+3.3V 24A Max
Safety Compliance*
Argentina IRAM
Canada UL60950 – CSA (60950 (UL and cUL)
China GB4943 (CCC Certification)
Europe, CE Mark EN60950 (complies with73/23/EEC)
Germany GS License
International IEC60950 (CB Report and Certificate)
Nordic Countries EMKO-TSE (74-SEC) 207/94
Russia GOST 50377-92
United States UL– 60950 – CSA 60950 (UL and cUL)
Electromagnetic Compatibility (Class A) (EMC)*
Australia/New Zealand AS/NZS 3548 (based on CISPR 22)
Canada ICES-003
China GB9254 & 17625 (CCC Certification)
Europe, CE Mark EN55022; EN55024 & EN61000-3-2;-3-3 (complies with 89/336/EEC)
International CISPR 22
Japan VCCI
Korea RRL, MIC 1997-41 & 1997-42
Russia GOST 29216-91 & 50628-95
Taiwan CNS13438
United States FCC, Part 15
*Safety and Class A EMC compliance is based on integration with a validated Intel® Server Board and configuration as outlined in the SR2300 Chassis Subassembly Installation Guide.