| Form Factor |
| 2U rack-mount server chassis for EIA Standard 310-D racks, validated with Intel® Server Board SE7501WV2 |
| Dimensions and Color |
| 3.4” (height) x 16.9” (width) x 24” (depth) (chassis without handles); 3.4” (height) x 18.9” (width) x 25.1” (depth) (chassis with handles); black trim |
| Hard Drive Support |
| Drive Bays |
Six one-inch hot-swap, one universal (for hot-swap drive, CD-ROM/floppy or DVD/floppy drive), one 3.5-inch full height |
| LVD SCSI Backplane |
Ultra320/Ultra160 support for up to seven one-inch hot-swap hard drives or six one-inch hot-swap drives and one slim-line CD-ROM/floppy drive module |
| System Cooling |
| 480W Power Supply Configuration |
Three 60mm fans mounted in the middle of the chassis and instrumented to provide RPM data for fan-failure prediction and detection (optional fourth fan available for redundant cooling); One 80mm x 38mm power-supply fan |
| 500W Power Supply Configuration |
Three 60mm fans mounted in the middle of the chassis and instrumented to provide RPM data for fan-failure prediction and detection (optional fourth fan available for redundant cooling); One 60mm x 38mm power-supply fan |
| Front Panel |
| Buttons and Switches |
Power/sleep, reset, NMI, and ID |
| LEDs |
Power, hard-drive activity, network activity, system ID, and general system status |
| Connectors |
VGA Video Port, USB Port |
| Security |
| A mechanical lock on the optional front bezel and an intrusion switch that can be monitored by Intel® Server Management |
| Environment |
| Ambient Temperature |
Operating (system): 10°C to +35°C, with maximum change not to exceed 10°C ; non-operating (system): -40°C to +70°C |
| Relative Humidity |
Non-operating: 90% @ 35°C non-condensing |
| Acoustics |
<55 dBA (rack-mount) in an idle state in an normal office environment (23°C) |
| Electrostatic Discharge |
15kV per Intel test specification |
| Standard Power Supply |
| AC Power Supply |
One fixed 480W EPS (non-redundant option) or one 500W hot-swap SSI TPS 1+0 (redundant option) |
| Max AC Voltage (500W) |
One fixed 480W EPS (non-redundant option) or one 500W hot-swap SSI TPS 1+0 (redundant option) |
| Max AC Voltage (480W) |
8.4A at 115V, 4.2A at 220V |
| +5V |
20A max |
| +5V Standby |
2A max |
| +12V1 |
18A sustained |
| +12V2 |
18A sustained |
| +3.3V |
24A Max |
| Safety Compliance* |
| Argentina |
IRAM |
| Canada |
UL60950 – CSA (60950 (UL and cUL) |
| China |
GB4943 (CCC Certification) |
| Europe, CE Mark |
EN60950 (complies with73/23/EEC) |
| Germany |
GS License |
| International |
IEC60950 (CB Report and Certificate) |
| Nordic Countries |
EMKO-TSE (74-SEC) 207/94 |
| Russia |
GOST 50377-92 |
| United States |
UL– 60950 – CSA 60950 (UL and cUL) |
| Electromagnetic Compatibility (Class A) (EMC)* |
| Australia/New Zealand |
AS/NZS 3548 (based on CISPR 22) |
| Canada |
ICES-003 |
| China |
GB9254 & 17625 (CCC Certification) |
| Europe, CE Mark |
EN55022; EN55024 & EN61000-3-2;-3-3 (complies with 89/336/EEC) |
| International |
CISPR 22 |
| Japan |
VCCI |
| Korea |
RRL, MIC 1997-41 & 1997-42 |
| Russia |
GOST 29216-91 & 50628-95 |
| Taiwan |
CNS13438 |
| United States |
FCC, Part 15 |
| *Safety and Class A EMC compliance is based on integration with a validated Intel® Server Board and configuration as outlined in the SR2300 Chassis Subassembly Installation Guide. |